# Inductance of a Stator Winding — Theory


<!-- WARNING: THIS FILE WAS AUTOGENERATED! DO NOT EDIT! -->

## Executive Summary

**Purpose:** the reference page for the `emachines.inductance` module.
It explains what the inductance of a winding is, which flux paths make
it up, how the phase values relate to the synchronous and dq inductances
used in motor models, and what an inductance measurement actually
contains. Every part is mapped to the notebook and function that
computes it.

**Reading order:** this page → [Stator and Slot
Geometry](inductance_geometry.html) (the inputs) → [Air-Gap
Inductance](inductance_airgap.html) (the first part computed) → the
leakage notebooks as they are added.

**Assumptions used throughout the module (linear model):** iron of
infinite permeability, no saturation, no eddy currents, a smooth
(non-salient) rotor. Saturation is a later MEC step.

## 1. What the inductance of a winding is

**Flux linkage.** A coil of *N* turns, each turn enclosing flux
*Φ*<sub>*k*</sub>, links

$$\lambda = \sum\_{k=1}^{N} \Phi_k \quad (= N\Phi \text{ when every turn encloses the same flux}).$$

The voltage across the coil is *v* = *R* *i* + *d**λ*/*d**t*. In a
distributed winding different turns enclose different amounts of flux,
because they sit in different slots and span different teeth. Counting
that correctly is the job of the *winding function* (see [Air-Gap
Inductance](inductance_airgap.html)).

**Inductance.** In a linear magnetic circuit the flux is proportional to
the current, so

$$L = \frac{\lambda}{i} = N^2\\\mathcal{P}, \qquad W\_{mag} = \tfrac12 L i^2,$$

with 𝒫 the permeance of the flux path (𝒫 = *μ*<sub>0</sub>*A*/*ℓ* for a
uniform air path of area *A* and length *ℓ*). Inductance is therefore
*turns squared times the permeance of the path the flux takes*. Since a
winding drives flux along several paths in parallel, its inductance is a
sum of parts, one per path (section 2).

**Several phases: self and mutual.** With *m* phases every phase links
flux driven by every other phase:

$$\boldsymbol{\lambda} = \mathbf{L}\\\mathbf{i}, \qquad L\_{xy} = \left.\frac{\lambda_x}{i_y}\right|\_{\text{only } y \text{ excited}}, \qquad W\_{mag} = \tfrac12\\\mathbf{i}^T\mathbf{L}\\\mathbf{i}.$$

- *L*<sub>*x**x*</sub> (the diagonal) is the **self inductance** of
  phase *x*: flux of phase *x* linking phase *x*.
- *L*<sub>*x**y*</sub> (off-diagonal) is the **mutual inductance**: flux
  of phase *y* linking phase *x*.
  *L*<sub>*x**y*</sub> = *L*<sub>*y**x*</sub> (reciprocity), so **L** is
  symmetric.

<figure>
<img src="images/self_mutual.svg"
alt="Two-pole stator with phase A and phase B coils 120 degrees apart. The flux of a current in phase A crosses the rotor vertically and returns round the yoke. All of it links coil A, giving L_aa; coil B is turned 120 degrees from the flux and links cos 120 = -1/2 of it, so the air-gap mutual inductance is -L_m/2." />
<figcaption aria-hidden="true">Two-pole stator with phase A and phase B
coils 120 degrees apart. The flux of a current in phase A crosses the
rotor vertically and returns round the yoke. All of it links coil A,
giving L_aa; coil B is turned 120 degrees from the flux and links cos
120 = -1/2 of it, so the air-gap mutual inductance is
-L_m/2.</figcaption>
</figure>

For a 3-phase winding the air-gap mutual is negative: the axes are 120°
apart, so phase B links $\cos 120^\circ = -\tfrac12$ of the air-gap flux
of phase A.

## 2. Where the flux goes: the parts of the inductance

<figure>
<img src="images/flux_paths.svg"
alt="Unrolled stator and rotor cross-section and a side view. Blue: main flux, down one tooth, across the gap, along the rotor and back up another tooth. Orange: slot leakage, crossing the slot from tooth to tooth and closing through the yoke. Green: tooth-tip leakage, crossing the slot opening between the two tooth tips. Purple: end-winding leakage, circling the end turns outside the stack." />
<figcaption aria-hidden="true">Unrolled stator and rotor cross-section
and a side view. Blue: main flux, down one tooth, across the gap, along
the rotor and back up another tooth. Orange: slot leakage, crossing the
slot from tooth to tooth and closing through the yoke. Green: tooth-tip
leakage, crossing the slot opening between the two tooth tips. Purple:
end-winding leakage, circling the end turns outside the
stack.</figcaption>
</figure>

The current in a phase drives flux along four kinds of path. Each has
its own permeance, so each gives its own part of the inductance:

<table>
<colgroup>
<col style="width: 18%" />
<col style="width: 32%" />
<col style="width: 12%" />
<col style="width: 38%" />
</colgroup>
<thead>
<tr>
<th>Path (colour above)</th>
<th>Where the flux goes</th>
<th>Part of <span class="math inline"><em>L</em></span></th>
<th>What it depends on</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>Main / air-gap</strong> (blue)</td>
<td>down a tooth, across the gap, through the rotor, back up another
tooth</td>
<td><span
class="math inline"><em>L</em><sub><em>a</em><em>g</em></sub> = <em>L</em><sub><em>m</em></sub> + <em>L</em><sub><em>δ</em></sub></span></td>
<td>winding distribution, bore radius, stack length, effective gap</td>
</tr>
<tr>
<td><strong>Slot leakage</strong> (orange)</td>
<td>across the slot from tooth to tooth, never reaching the gap</td>
<td><span
class="math inline"><em>L</em><sub><em>s</em><em>l</em><em>o</em><em>t</em></sub></span></td>
<td>slot shape, and <strong>where in the slot each conductor
sits</strong></td>
</tr>
<tr>
<td><strong>Tooth-tip leakage</strong> (green)</td>
<td>across the slot opening between the tooth tips</td>
<td><span
class="math inline"><em>L</em><sub><em>t</em><em>t</em></sub></span></td>
<td>opening width <span
class="math inline"><em>b</em><sub>0</sub></span>, tip height, air
gap</td>
</tr>
<tr>
<td><strong>End-winding leakage</strong> (purple)</td>
<td>around the end turns, in air outside the stack</td>
<td><span
class="math inline"><em>L</em><sub><em>e</em><em>w</em></sub></span></td>
<td>end-turn length and shape, coil pitch</td>
</tr>
</tbody>
</table>

(A skewed stator or rotor adds a skew leakage; it is not modelled.)

**The air-gap part splits in two.** The flux that crosses the gap is
described by the winding function, a staircase round the bore. Its
Fourier series has the *working harmonic* *ν* = *p*, which matches the
rotor’s pole count and produces the torque, and every other harmonic:

- **magnetising inductance *L*<sub>*m*</sub>** — the working harmonic
  only;
- **harmonic (differential) leakage *L*<sub>*δ*</sub>** — all the other
  harmonics. This flux does cross the gap, but it has the wrong pole
  count to make steady torque with the rotor, so as far as the energy
  conversion goes it is leakage. Distributed windings have little
  (*L*<sub>*δ*</sub>/*L*<sub>*m*</sub> ≈ 1–10 %); tooth-coil windings
  have a lot (about 100 % for 12 slots / 10 poles).

**Leakage** is everything that is not the magnetising part:

*L*<sub>*σ*</sub> = *L*<sub>*δ*</sub> + *L*<sub>*s**l**o**t*</sub> + *L*<sub>*t**t*</sub> + *L*<sub>*e**w*</sub>.

<figure>
<img src="images/inductance_components.svg"
alt="Tree: the measured self inductance L_aa splits into the air-gap part (magnetising L_m and harmonic leakage L_delta, both computed in 03_airgap) and local leakage that never reaches the rotor (slot, tooth tip and end winding, computed in later notebooks). Total leakage is L_delta plus slot plus tooth tip plus end winding." />
<figcaption aria-hidden="true">Tree: the measured self inductance L_aa
splits into the air-gap part (magnetising L_m and harmonic leakage
L_delta, both computed in 03_airgap) and local leakage that never
reaches the rotor (slot, tooth tip and end winding, computed in later
notebooks). Total leakage is L_delta plus slot plus tooth tip plus end
winding.</figcaption>
</figure>

**Why conductor position in the slot matters.** Slot-leakage flux
crosses the slot at some depth *y* and links only the conductors *below*
that line (deeper in the slot). A conductor at the slot bottom is linked
by flux crossing at every depth; one next to the opening is linked by
very little. So layers at different depths have different slot leakage,
and phases that share a slot are coupled by it (a mutual slot leakage).
That is the source of the layer-to-layer imbalance in windings where
each phase sits in its own layer.

## 3. From the phase matrix to the inductances used in motor models

For a balanced 3-phase winding, write the self inductance as
*L*<sub>*a**a*</sub> and the mutual between any two phases as
*L*<sub>*a**b*</sub>. Each part of section 2 contributes to both:

$$L\_{aa} = L_m + L\_{\sigma,self}, \qquad L\_{ab} = -\tfrac12 L_m + L\_{\sigma,mut}.$$

*L*<sub>*σ*, *m**u**t*</sub> comes from the harmonic leakage and from
slot and end-winding leakage where two phases share a slot or overlap at
the ends.

**Synchronous (positive-sequence) inductance.** With balanced currents
*i*<sub>*a*</sub> + *i*<sub>*b*</sub> + *i*<sub>*c*</sub> = 0:

*λ*<sub>*a*</sub> = *L*<sub>*a**a*</sub>*i*<sub>*a*</sub> + *L*<sub>*a**b*</sub>(*i*<sub>*b*</sub> + *i*<sub>*c*</sub>) = (*L*<sub>*a**a*</sub> − *L*<sub>*a**b*</sub>) *i*<sub>*a*</sub>,

$$\boxed{L_s = L\_{aa} - L\_{ab} = \tfrac32 L_m + (L\_{\sigma,self} - L\_{\sigma,mut})}$$

For *m* phases the magnetising part is $\tfrac{m}{2} L_m$.
$\tfrac32 L_m$ is what induction-machine texts call the magnetising
inductance *L*<sub>*M*</sub>; take care which one a formula means.

**Zero sequence.** With equal currents in all phases,
*L*<sub>0</sub> = *L*<sub>*a**a*</sub> + 2*L*<sub>*a**b*</sub>. The
working harmonic cancels, so only leakage (and triplen harmonics)
remain. This matters for open-end-winding drives and for checking a
winding.

**dq inductances.** For a smooth rotor
*L*<sub>*d*</sub> = *L*<sub>*q*</sub> = *L*<sub>*s*</sub>. For a salient
or interior-PM rotor the air-gap part depends on rotor position:
*L*<sub>*a**a*</sub>(*θ*) ≈ *L*<sub>*a*0</sub> + *L*<sub>*a*2</sub>cos 2*θ*,
and *L*<sub>*d*</sub> ≠ *L*<sub>*q*</sub>. The leakage parts barely
change with rotor position. This module computes the smooth-rotor value.
A surface-PM rotor is handled by enlarging the effective gap to
*k*<sub>*C*</sub>(*g* + *h*<sub>*m*</sub>/*μ*<sub>*r*</sub>) (the magnet
behaves almost like air).

**Unbalanced windings.** When the phases are not identical, **L** is no
longer circulant and these single numbers are not enough.
`phase_imbalance` reports how far **L** is from balanced, including how
much a balanced current set couples into the negative and zero
sequences.

``` python
import numpy as np
from emachines.inductance import StatorGeometry, SlotGeometry, airgap_inductance, phase_imbalance
from emachines.winding import WindingPattern
```

``` python
# The 36-slot example from the geometry notebook: air-gap part only (leakage parts come later)
stator = StatorGeometry(Q=36, r_bore=60e-3, g=0.8e-3, l_stk=100e-3, h_y=12e-3, l_ew=22e-3,
                        slot=SlotGeometry.semi_closed(b0=2.5e-3, h0=1e-3, h1=1.5e-3, bs=6e-3, hs=18e-3, t=0.5))
pat = WindingPattern.distributed(36, 4, pitch=7, turns=10, parallel_paths=2)
L, Lm = airgap_inductance(pat, stator), airgap_inductance(pat, stator, "magnetising")
Laa, Lab = L[0, 0], L[0, 1]
print(f"L_aa = {Laa*1e3:.3f} mH, L_ab = {Lab*1e3:.3f} mH (≈ -L_aa/2 + harmonic part)")
print(f"synchronous L_s = L_aa - L_ab = {(Laa-Lab)*1e3:.3f} mH;  3/2·L_m = {1.5*Lm[0,0]*1e3:.3f} mH")
print(f"line-to-line (star) L_LL = 2(L_aa - L_ab) = {2*(Laa-Lab)*1e3:.3f} mH")
print(f"zero sequence L_0 = L_aa + 2 L_ab = {(Laa+2*Lab)*1e3:.4f} mH")
assert np.isclose(phase_imbalance(L)["L_positive"], Laa - Lab)
```

    L_aa = 8.162 mH, L_ab = -3.858 mH (≈ -L_aa/2 + harmonic part)
    synchronous L_s = L_aa - L_ab = 12.020 mH;  3/2·L_m = 11.888 mH
    line-to-line (star) L_LL = 2(L_aa - L_ab) = 24.040 mH
    zero sequence L_0 = L_aa + 2 L_ab = 0.4452 mH

## 4. What a measurement contains

An inductance measurement at the terminals contains **all** the parts in
section 2 at once: magnetising, harmonic, slot, tooth-tip and
end-winding (plus a little from the leads). What it measures depends on
how the phases are connected:

<table>
<colgroup>
<col style="width: 18%" />
<col style="width: 30%" />
<col style="width: 20%" />
<col style="width: 32%" />
</colgroup>
<thead>
<tr>
<th>Test</th>
<th>Connection</th>
<th>Reads</th>
<th>For a balanced winding</th>
</tr>
</thead>
<tbody>
<tr>
<td>Single phase</td>
<td>one phase, the others open</td>
<td><span
class="math inline"><em>L</em><sub><em>a</em><em>a</em></sub></span></td>
<td><span
class="math inline"><em>L</em><sub><em>m</em></sub> + <em>L</em><sub><em>σ</em>, <em>s</em><em>e</em><em>l</em><em>f</em></sub></span></td>
</tr>
<tr>
<td>Line to line (star, LCR meter on two terminals)</td>
<td>phases a and b in series, opposing</td>
<td><span
class="math inline"><em>L</em><sub><em>a</em><em>a</em></sub> + <em>L</em><sub><em>b</em><em>b</em></sub> − 2<em>L</em><sub><em>a</em><em>b</em></sub></span></td>
<td><span class="math inline">2<em>L</em><sub><em>s</em></sub></span> →
<span
class="math inline"><em>L</em><sub><em>s</em></sub> = <em>L</em><sub><em>L</em><em>L</em></sub>/2</span></td>
</tr>
<tr>
<td>Series aiding / opposing</td>
<td>a and b in series, both ways</td>
<td><span
class="math inline"><em>L</em><sub><em>a</em><em>a</em></sub> + <em>L</em><sub><em>b</em><em>b</em></sub> ± 2<em>L</em><sub><em>a</em><em>b</em></sub></span></td>
<td>difference / 4 <span
class="math inline"> = <em>L</em><sub><em>a</em><em>b</em></sub></span></td>
</tr>
<tr>
<td>Rotor at aligned / quadrature position</td>
<td>line to line, rotor locked</td>
<td><span class="math inline">2<em>L</em><sub><em>d</em></sub></span> /
<span class="math inline">2<em>L</em><sub><em>q</em></sub></span>
(salient rotor)</td>
<td>half the min and max of <span
class="math inline"><em>L</em><sub><em>L</em><em>L</em></sub>(<em>θ</em>)</span></td>
</tr>
<tr>
<td>Three phases in series</td>
<td>a + b + c, all the same direction</td>
<td><span class="math inline">3<em>L</em><sub>0</sub></span></td>
<td>leakage only</td>
</tr>
</tbody>
</table>

**Effects in a measurement that the linear model leaves out**:

- **Saturation.** Inductance falls as current rises. An LCR meter drives
  a tiny current and sees the unsaturated value, sometimes even lower
  than the model, because iron permeability is low at very small flux
  density.
- **Permanent magnets** bias the iron. The d-axis path is partly
  saturated by the magnet, so *L*<sub>*d*</sub> comes out below the
  air-only estimate.
- **Frequency.** Eddy currents in laminations, magnets, a retaining
  sleeve or a rotor cage push flux out and lower the measured inductance
  as frequency rises. In an induction machine the cage almost shorts the
  air-gap flux, so a locked-rotor test measures roughly the leakage, not
  *L*<sub>*m*</sub>.
- **Losses** show up as a series resistance that rises with frequency
  (iron loss, skin and proximity effect).

**Comparing model and measurement:** use a low current, a low frequency,
a known rotor position (or the rotor removed), and the same connection
as the formula. Expect the model to read a little high for a PM machine.

## 5. Where each part is computed

<table>
<colgroup>
<col style="width: 30%" />
<col style="width: 14%" />
<col style="width: 22%" />
<col style="width: 24%" />
<col style="width: 10%" />
</colgroup>
<thead>
<tr>
<th>Quantity</th>
<th>Symbol</th>
<th>Notebook</th>
<th>Function</th>
<th>Status</th>
</tr>
</thead>
<tbody>
<tr>
<td>Winding layout (turns of each phase at each slot position)</td>
<td><span
class="math inline"><em>N</em><sub><em>x</em>, <em>i</em></sub></span></td>
<td><a href="winding_pattern.html">Winding Patterns</a></td>
<td><code>WindingPattern</code></td>
<td>done</td>
</tr>
<tr>
<td>Stator and slot geometry</td>
<td><span
class="math inline"><em>r</em><sub><em>b</em><em>o</em><em>r</em><em>e</em></sub>, <em>g</em>, <em>l</em><sub><em>s</em><em>t</em><em>k</em></sub>, <em>b</em><sub>0</sub>, …</span></td>
<td><a href="inductance_geometry.html">Stator and Slot Geometry</a></td>
<td><code>StatorGeometry</code>, <code>SlotGeometry</code></td>
<td>done</td>
</tr>
<tr>
<td>Air-gap inductance (magnetising + harmonic leakage)</td>
<td><span
class="math inline"><em>L</em><sub><em>a</em><em>g</em></sub>, <em>L</em><sub><em>m</em></sub>, <em>L</em><sub><em>δ</em></sub></span></td>
<td><a href="inductance_airgap.html">Air-Gap Inductance</a></td>
<td><code>airgap_inductance</code></td>
<td>done</td>
</tr>
<tr>
<td>Phase imbalance report</td>
<td>—</td>
<td><a href="inductance_airgap.html">Air-Gap Inductance</a></td>
<td><code>phase_imbalance</code></td>
<td>done</td>
</tr>
<tr>
<td>Slot leakage by conductor position, tooth-tip leakage</td>
<td><span
class="math inline"><em>L</em><sub><em>s</em><em>l</em><em>o</em><em>t</em></sub>, <em>L</em><sub><em>t</em><em>t</em></sub></span></td>
<td><a href="inductance_slot.html">Slot and Tooth-Tip Leakage</a></td>
<td><code>slot_leakage_inductance</code>,
<code>slot_permeance</code></td>
<td>done</td>
</tr>
<tr>
<td>End-turn length, phase resistance, end-winding leakage
(empirical)</td>
<td><span
class="math inline"><em>l</em><sub><em>e</em><em>n</em><em>d</em></sub>, <em>R</em>, <em>L</em><sub><em>e</em><em>w</em></sub></span></td>
<td><a href="inductance_end_winding.html">End Turns, Phase Resistance
and End-Winding Leakage</a></td>
<td><code>EndTurn</code>, <code>phase_resistance</code>,
<code>end_winding_inductance</code></td>
<td>done</td>
</tr>
<tr>
<td>All parts together, synchronous and zero sequence, winding
comparison</td>
<td><span
class="math inline"><strong>L</strong>, <em>L</em><sub><em>s</em></sub>, <em>L</em><sub>0</sub></span></td>
<td><a href="inductance_stator.html">Total Stator Inductance</a></td>
<td><code>stator_inductances</code>, <code>compare_windings</code></td>
<td>done</td>
</tr>
<tr>
<td>End-winding leakage by filaments (Biot–Savart)</td>
<td><span
class="math inline"><em>L</em><sub><em>e</em><em>w</em></sub></span></td>
<td>later</td>
<td>—</td>
<td>planned</td>
</tr>
<tr>
<td>Saturation (magnetic equivalent circuit)</td>
<td>—</td>
<td>later</td>
<td>—</td>
<td>planned</td>
</tr>
</tbody>
</table>

## Symbols

<table style="width:100%;">
<colgroup>
<col style="width: 18%" />
<col style="width: 70%" />
<col style="width: 12%" />
</colgroup>
<thead>
<tr>
<th>Symbol</th>
<th>Meaning</th>
<th>Unit</th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="math inline"><em>Q</em></span>, <span
class="math inline"><em>P</em></span>, <span
class="math inline"><em>p</em></span>, <span
class="math inline"><em>m</em></span></td>
<td>slots, poles, pole pairs (<span
class="math inline"><em>P</em>/2</span>), phases</td>
<td>—</td>
</tr>
<tr>
<td><span
class="math inline"><em>N</em><sub><em>x</em>, <em>i</em></sub></span></td>
<td>turns of phase <span class="math inline"><em>x</em></span> in slot
<span class="math inline"><em>i</em></span> per ampere of phase current
(signed, divided by parallel paths)</td>
<td>—</td>
</tr>
<tr>
<td><span
class="math inline"><em>W</em><sub><em>x</em>, <em>i</em></sub></span></td>
<td>winding function of phase <span
class="math inline"><em>x</em></span> over tooth <span
class="math inline"><em>i</em></span></td>
<td>—</td>
</tr>
<tr>
<td><span class="math inline"><em>λ</em></span>, <span
class="math inline"><em>Φ</em></span></td>
<td>flux linkage, flux</td>
<td>Wb</td>
</tr>
<tr>
<td><span
class="math inline"><em>L</em><sub><em>x</em><em>y</em></sub></span></td>
<td>inductance matrix entry (self if <span
class="math inline"><em>x</em> = <em>y</em></span>)</td>
<td>H</td>
</tr>
<tr>
<td><span
class="math inline"><em>L</em><sub><em>m</em></sub></span></td>
<td>magnetising inductance (working harmonic, per phase self)</td>
<td>H</td>
</tr>
<tr>
<td><span class="math inline"><em>L</em><sub><em>δ</em></sub></span>,
<span
class="math inline"><em>σ</em><sub><em>δ</em></sub> = <em>L</em><sub><em>δ</em></sub>/<em>L</em><sub><em>m</em></sub></span></td>
<td>harmonic (differential) leakage, its ratio to <span
class="math inline"><em>L</em><sub><em>m</em></sub></span></td>
<td>H, —</td>
</tr>
<tr>
<td><span
class="math inline"><em>L</em><sub><em>s</em><em>l</em><em>o</em><em>t</em></sub></span>,
<span
class="math inline"><em>L</em><sub><em>t</em><em>t</em></sub></span>,
<span
class="math inline"><em>L</em><sub><em>e</em><em>w</em></sub></span></td>
<td>slot, tooth-tip, end-winding leakage</td>
<td>H</td>
</tr>
<tr>
<td><span class="math inline"><em>L</em><sub><em>s</em></sub></span>,
<span class="math inline"><em>L</em><sub>0</sub></span>, <span
class="math inline"><em>L</em><sub><em>d</em></sub></span>, <span
class="math inline"><em>L</em><sub><em>q</em></sub></span></td>
<td>synchronous (positive sequence), zero sequence, d- and q-axis</td>
<td>H</td>
</tr>
<tr>
<td><span class="math inline"><em>g</em></span>, <span
class="math inline"><em>g</em><sub><em>e</em></sub> = <em>k</em><sub><em>C</em></sub><em>g</em></span></td>
<td>mechanical and effective (Carter) air gap</td>
<td>m</td>
</tr>
<tr>
<td><span
class="math inline"><em>r</em><sub><em>g</em></sub> = <em>r</em><sub><em>b</em><em>o</em><em>r</em><em>e</em></sub> − <em>g</em>/2</span></td>
<td>radius at mid-gap</td>
<td>m</td>
</tr>
<tr>
<td><span
class="math inline"><em>l</em><sub><em>s</em><em>t</em><em>k</em></sub></span></td>
<td>stack length</td>
<td>m</td>
</tr>
<tr>
<td><span class="math inline"><em>μ</em><sub>0</sub></span></td>
<td><span class="math inline">4<em>π</em> × 10<sup>−7</sup></span></td>
<td>H/m</td>
</tr>
<tr>
<td><span class="math inline"><em>ν</em></span></td>
<td>harmonic order, in pole pairs round the whole gap</td>
<td>—</td>
</tr>
</tbody>
</table>

## References

- Sudhoff, S.D. *Power Magnetic Devices* (2nd ed.), chapter 8 and
  [*Distributed Windings and Rotating
  Fields*](https://engineering.purdue.edu/~sudhoff/ee595s/TADES-chapter4.pdf),
  Purdue notes — winding functions, air-gap and leakage inductance.
- Pyrhönen, J., Jokinen, T., Hrabovcová, V. (2014). *Design of Rotating
  Electrical Machines* (2nd ed.). Wiley, chapter 4 — magnetising
  inductance and the leakage components (air-gap harmonic, slot,
  tooth-tip, end-winding, skew).
- Krause, P.C., Wasynczuk, O., Sudhoff, S.D., Pekarek, S. (2013).
  *Analysis of Electric Machinery and Drive Systems* (3rd ed.).
  Wiley-IEEE Press — phase, synchronous and dq inductances.
- IEEE Std 1812-2014, *Guide for Testing Permanent Magnet Machines* —
  standstill inductance tests.